Hp Bladesystem C7000 Enclosure Manual
- Hp C7000 Chassis Manual
- Hp Bladesystem C7000 Enclosure Setup
- Hp C7000 Pdf
- C7000 Onboard Administrator User Guide
- Hp Bladesystem C7000 Enclosure Manual Download
View and Download HP c7000 instruction manual online. 3.25 Mb 15 User Manual.pdf. Manuals HP. HP BladeSystem specification for a c. QuickSpecs HP BladeSystem c7000 Enclosure HP BladeSystem c-Class Overview DA - 12810€€€Worldwide — Version 53 — March 31, 2014 Page€ 3. HP c3000 Enclosure For customers that need a smaller system the c3000 is the perfect solution. Supporting up to 8 blades.
HPE BladeSystem c3000 Enclosure Setup and Installation Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. 3 Removal and replacement procedures NOTE: The HP BladeSystem c7000 Carrier-Grade Enclosure is similar to the HP BladeSystem c7000. Refer to the HP BladeSystem c7000 Enclosure Maintenance and Service Guide for the following removal and replacement procedures: Server blades Device bay shelves and shelf blanks.
Configuring the HP BladeSystem c7000 enclosure and enclosure devices 168
QuickSpecs HPE BladeSystem c3000 Enclosure. Standard Features. HPE BladeSystem c-Class c3000 Enclosure A HPE BladeSystem solutions start with an either a c7000 or c3000 enclosure. For the c3000 enclosure, key enclosure components include hot -plug power supplies, hot plug HPE Active Cool 100 Fans, and an optional. The HP BladeSystem c7000 enclosure has a fully redundant design with redundant interconnections between servers and interconnect modules. The enclosure contains a NonStop signal midplane and a power backplane that have no active components. HPE BladeSystem c7000 Enclosure Setup and Installation Guide Abstract This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical support. This guide is for an experienced service technician. Hewlett Packard Enterprise assumes you are qualified in the.
All Enclosure Firmware Management features are available through both the Onboard Administrator GUI
and CLI. The Onboard Administrator user role and bay permissions control the Enclosure Firmware
Management settings and ability to view the firmware information.
User role
Modify settings or
scheduled update
Initiate manual
discovery or update
View firmware versions
Onboard Administrator
administrator or operator
Yes
Yes, administrator only
Yes
Server administrator or
operator
No
Yes, administrator only
Yes, for permitted server bays
Onboard Administrator
user
No
No
Yes, for permitted bays
Enabling Enclosure Firmware Management
The Enable Enclosure Firmware Management check box globally enables or disables (default setting)
Enclosure Firmware Management. When disabled, you cannot start any manual Enclosure Firmware
Management operations. Any previously configured automatic or scheduled operation does not occur. If the
setting is changed from enabled to disabled, any in-progress Enclosure Firmware Management discoveries
or updates continue until they are finished.
IMPORTANT:
After Enclosure Firmware Management operations (updates and
discoveries) have begun on a server, you cannot stop these operations. Ensure that
your enclosure is IPv6-enabled before using an IPv6 address for the Firmware
Management ISO.
Enclosure Firmware Management is not supported on the following Onboard Administrator hardware
modules:
•
HP BladeSystem c3000 Onboard Administrator (HP part number 448589-B21, 461514-B21)
•
HP BladeSystem c7000 Onboard Administrator (HP part number 412142-B21)
Enclosure Firmware Management cannot be enabled unless the active Onboard Administrator hardware
module is supported. If you attempt to enable Enclosure Firmware Management when the active Onboard
Administrator is not supported, an error message appears:
Enclosure Firmware Management is not supported on the active OA hardware
present.
If the standby Onboard Administrator module is unsupported, a warning message appears:
Beginning hardanger patterns free download. Enclosure Firmware Management is not supported on the standby OA hardware
present. The feature will be disabled if the standby OA becomes Active.
Enclosure Firmware Management will not work reliably and should not be used on slow network links (less
than 100Mbps).
While running Enclosure Firmware Management operations, the Onboard Administrator response time
might be slower than usual, and during brief intervals, enclosure status might be reported as degraded. You
can safely ignore messages or alert conditions of this nature while the operations are in progress.
Enclosure Firmware Management fails on any blade if SSH is disabled in the blade's iLO configuration
settings. By default, SSH is enabled in iLO.
Configuring the HP BladeSystem c7000 enclosure and enclosure devices 120
Field
Possible value
Description
System Location
0 to 20 characters including all
printable characters and the
space
The SNMP location of the enclosure typically
used to identify the physical or topographical
location of the Onboard Administrator.
System Contact
0 to 20 characters including all
printable characters and the
space
The name of the system contact, used to identify
an individual or group of individuals who are to
be contacted in the event of any status change
in the HP BladeSystem Onboard Administrator.
Read Community
0 to 20 characters including all
printable characters and the
space
The Read Community string enables the client to
read information but not to manipulate the alerts
or status of the HP BladeSystem Onboard
Hp C7000 Chassis Manual
Administrator through SNMPv1 or SNMPv2.
The default community name is 'public' and
will allow a user to receive notification traps
and alerts, but not to change or manipulate the
status.
Hp Bladesystem C7000 Enclosure Setup
Write Community
0 to 20 characters including all
printable characters and the
space
The Write Community string enables the client
to manipulate alerts of HP BladeSystem
Onboard Administrator status through SNMPv1
or SNMPv2. You can remotely clear alerts and
mark them as 'viewed' or otherwise through
their SNMP management client through the
SNMP agents.
Engine ID String
1 to 27 printable characters,
final Engine ID will be a
hexadecimal string that begins
with '0x' and is derived from
Hp C7000 Pdf
this string
The Engine ID String is used to create the engine
ID hex value.
The engine ID is combined with the user name to
create a SNMPv3 user for each enclosure.
C7000 Onboard Administrator User Guide
When the engine ID is unique to an enclosure,
users with the same name on different
enclosures are unique.
The Engine ID string defaults to the serial
number of the enclosure.
After editing any field in this subcategory, to save the changes, click Apply.
Adding SNMP alert destinations
To remove a current SNMP alert destination, select the check box, and click Delete.
To add a new SNMP alert destination, click New. The Add SNMP Alert screen appears.
To send a test SNMP trap to all of the configured trap destinations, click Send Test Alert. You must enable
SNMP to use this function.